Korea Fire Institute of Industry & Technology
  • product Products List
    • home Home >
    • Pdoduct >
    • Products List
  • list image

  • Automatic fire extinguisher(Shut off part)
    *Shut off part It can automatically open and close the gas valve with the control signal of receiver. ☞ There is a handle-operational type which is available to add to an installed gas valve, and valve linking type which is available to assemble with shut off device after valve installation. Please contact us for any request in purchase. *Specifications 1.SV-20F -Division : AFE-2050F -Size : Input15,20A/Output15A -shut off method : Electric valve type -shut off speed : 0.5 sec -Pressure in use : Low Pressure(0.1kg / ㎠) -Durability : More than 60,000times -Operating control method : Solenoid Method -How to open/close : Remote and Manual Open/Close method -Size(mm) :W92*H117.5*D45 -Weight(g) : 680 2.SV-20I -Division : AFE-2050I -Size : Input15,20A/Output15,20A -shut off method : Electric valve type -shut off speed : 0.5 sec -Pressure in use : Low Pressure(0.1kg / ㎠) -Durability : More than 60,000times -Operating control method : Solenoid Method -How to open/close : Remote and Manual Open/Close method
    go to inquiry
  • list image

  • Automatic fire extinguisher(Shut off part)
    *Shut off part It can automatically open and close the gas valve with the control signal of receiver. ☞ There is a handle-operational type which is available to add to an installed gas valve, and valve linking type which is available to assemble with shut off device after valve installation. *Specifications 1.SV-20B -Division : AFE-2050B -Size : 20A -shut off method : Handle Operational -Torque(Max) : 65kgf · com -shut off speed : Within 10seconds -Pressure in use : Low Pressure(0.1kg / ㎠) -Durability : More than 6,000times -Operating control method : Motor Operation limit S/W method -How to open/close : Remote and Manual Open/Close method -Size(mm) : W110*H100*D65 -Weight(g) : 250 2.SV-20H -Division : AFE-2050H -Size : 20A -shut off method : Valve Operational -Torque(Max) : 65kgf · com -shut off speed : Within 10seconds -Pressure in use : Low Pressure(0.1kg / ㎠) -Durability : More than 6,000times -Operating control method : Motor Operation limit S/W method -How to open/close : Remote and Manual O
    go to inquiry
  • list image

  • Automatic fire extinguisher(Fire extinguisher)
    *Automatic fire extinguishing function When the temperature rises up by overheated oil or foods, it detects the 1st temperature (100℃) with the temperature sensor, and Shut off gas supply by operating the shut off valve and operated alarm. If the fire on oil or foods is still remaining alive, and the temperature continues to rise up to the 2nd temperature (139℃), detecting it with the temperature sensor, it automatically puts out the fire by operating the fire extinguisher with the 2nd alarm sound. *Gas leak inspecting function If gas leaks from a gas range or gas pipe, the gas leak detector inspects the change in the air, and if over average density (0.06~1.25%) of gas is detected, it cuts off gas by operating a shut off valve with alarm sound. *Overheating detecting function of range By sensing the temperature change of a gas range with a temperature sensor, if it is over than average(100℃), it cuts off gas supply by operating a shut off valve with alarm sound. *Fire extinguisher When fire occurs, with the working of operative device, the outlet of the fire extinguishing media is automatically open and it sprays the extinguishing m
    go to inquiry
  • list image

  • Automatic fire extinguisher(Spray nozzle / Temperature detection part)
    *Automatic fire extinguishing function When the temperature rises up by overheated oil or foods, it detects the 1st temperature (100℃) with the temperature sensor, and Shut off gas supply by operating the shut off valve and operated alarm. If the fire on oil or foods is still remaining alive, and the temperature continues to rise up to the 2nd temperature (139℃), detecting it with the temperature sensor, it automatically puts out the fire by operating the fire extinguisher with the 2nd alarm sound. *Gas leak inspecting function If gas leaks from a gas range or gas pipe, the gas leak detector inspects the change in the air, and if over average density (0.06~1.25%) of gas is detected, it cuts off gas by operating a shut off valve with alarm sound. *Overheating detecting function of range By sensing the temperature change of a gas range with a temperature sensor, if it is over than average(100℃), it cuts off gas supply by operating a shut off valve with alarm sound. *Spray nozzle / Temperature detection part By checking the temperature around the gas range, it sends the data of electric change earned from temperature change to the central process unit of receiver. With the data of 1st temperature sensor, it detects or prevents the fire, and with the data of 2nd temperature sensor, it detects fire and controls the operation of operative devices. ☞ Fire extinguisher media can be sprayed with the change of temperature caused by lighter or other heat. In this case, we do not have responsibility and can check the cause. *Specification 1st Temperature sensor -Type : Temperature sensor type -Operation temperature : 110℃ -Operation time : Within ‘0’second (Operation temperature 125%) 2nd Temperature sensor -Type
    go to inquiry
  • list image

  • Automatic fire extinguisher(Receiving part/ Control part)
    *Automatic fire extinguishing function When the temperature rises up by overheated oil or foods, it detects the 1st temperature (100℃) with the temperature sensor, and Shut off gas supply by operating the shut off valve and operated alarm. If the fire on oil or foods is still remaining alive, and the temperature continues to rise up to the 2nd temperature (139℃), detecting it with the temperature sensor, it automatically puts out the fire by operating the fire extinguisher with the 2nd alarm sound. *Gas leak inspecting function If gas leaks from a gas range or gas pipe, the gas leak detector inspects the change in the air, and if over average density (0.06~1.25%) of gas is detected, it cuts off gas by operating a shut off valve with alarm sound. *Overheating detecting function of range By sensing the temperature change of a gas range with a temperature sensor, if it is over than average(100℃), it cuts off gas supply by operating a shut off valve with alarm sound. *Receiving part/ Control part Through central processing units, detecting and inspecting devices control operating systems and shut off devices, and operate buzzers, display current status, check the pressure of fire extinguisher and the status of tube, and show the parts with trouble. *Specifications -Voltage : AC 220V/ 60Hz -Power consumption : 6.1W -Redundant power supply : Ni-Cd Battery / DC 12V 600mAh -Operation temperature range : -10 ~ 50℃ -Exterior input/output signal : input/output with PLC productH/A, input/output with H/A product(limited to applicable model) *Function -Operation temperature
    go to inquiry
  • go list